EasyManua.ls Logo

NEC UNIVERGE NEAX 2000 IPS - Page 71

NEC UNIVERGE NEAX 2000 IPS
191 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 3 TERMINALS
UNIVERGE NEAX 2000 IPS General Description Page 67
Issue 5
Dterm Series i Line Conditions
Cable Length Note 1 Standard
with AC Adapter
Note 4
8DLC 300m (984ft)
Note 2
4DLC 300m (984ft) 1200m (3937ft)
Dterm 8 / 8D
2DLC 850m (2789ft) 1200m (3937ft)
8DLC 200m (656ft)
Note 2
4DLC 200m (656ft) 1200m (3937ft)
Dterm 16/16D
2DLC 850m (2789ft) 1200m (3937ft)
8DLC 200m (656ft)
Note 2
4DLC 200m (656ft) 1200m (3937ft)
Dterm 32/32D
2DLC 850m (2789ft) 1200m (3937ft)
8DLC - 300m (984ft)
4DLC - 1200m (3937ft)
Dterm Series i
DSS/BLF Console
Note 3
2DLC - 1200m (3937ft)
Note 1: Cable length is based on the following conditions.
Diameter of the cable is 0.5 mm.
The Protection arrester is not inserted between the terminal and PBX.
Note 2:
When using 8DLC card, it is not available for long line function, even if it is equipped
with AC Adapter.
Note 3:
The DSS/BLF Console requires local AC/DC supply.
Note 4:
DTR-2DT and DTR-4D terminals do not support long line adapters.