CHAPTER 3 TERMINALS
UNIVERGE NEAX 2000 IPS General Description Page 73
Issue 5
Dterm Series E Line Conditions
Loop Resistance Note 1
Standard 600 ohms Analog
Telephone Set
Option 2,500 ohms
Exchange Line 1,700 ohms Loop Start
Trunk
Tie or DID Line 2,500 ohms
Cable Length Note 2 Standard with AC Adapter
8DLC 300m (984ft)
Note 3
4DLC 300m (984ft) 1200m (3937ft)
Dterm 8 / 8D
2DLC 850m (2789ft) 1200m (3937ft)
8DLC 200m (656ft) Note 3
4DLC 200m (656ft) 1200m (3937ft)
Dterm 16/16D
2DLC 850m (2789ft) 1200m (3937ft)
8DLC 200m (656ft)
Note 3
4DLC 200m (656ft) 1200m (3937ft)
Dterm 32/32D
2DLC 850m (2789ft) 1200m (3937ft)
Dterm 8D-1IP
_ Max. 328 ft. between Ether/IP-PAD and
Router/ Switching Hub
Dterm 16D-1IP
_ Max. 328 ft. between Ether/IP-PAD and
Router/ Switching Hub
Dterm 32D-1IP
_ Max. 328 ft. between Ether/IP-PAD and
Router/ Switching Hub
8DLC - 300m (984ft)
4DLC - 1200m (3937ft)
Dterm Series E
DSS/BLF Console
Note 4
2DLC - 1200m (3937ft)
Attendant Terminal
Same as Dterm Series E
8DLC 300m (984ft)
Note 3
4DLC 350m (1148ft) 1200m (3937ft)
Operator
Position
SN716
Desk Console
2DLC 350m (1148ft) 1200m (3937ft)
Note 1: Loop resistance includes an internal resistance of telephone set or distant exchange.
Note 2: Cable length is based on the following conditions.
Diameter of the cable is 0.5 mm.
The Protection arrester is not inserted between the terminal and PBX.
Note 3: When using 8DLC card, it is not available for long line function, even if it is equipped
with AC Adapter.
Note 4: The DSS/BLF Console requires local AC/DC supply.