Chapter 1 MAINTENANCE SERVICES
1-10 NWA-033627-001 Rev.4.0
95ch1001.fm
FAULT MESSAGE
DESCRIPTION DATA
Assign the number of stations in line lockout to
give alarm.
(1)
(2)
01
01-99 : Number of lockout stations
NONE : No “Lockout Alarm Display”
Assign the number of detected faulty trunks to
give alarm.
[Australia Only]
(1)
(2)
06
01-99 : Number of Line Fault trunk
NONE : No detection
Assign the number of detected faulty trunks to
give alarm.
[Australia Only]
(1)
(2)
07
01-99 : Number of Line Fault trunk
NONE : No detection
Assign the time for monitoring long call dura-
tion of trunk call.
(1)
(2)
182
01-60 : 1-60 hours
NONE : 60 hours
D
CMEA
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
052 Communication error restoration between
Main Unit and Remote Unit NOTE 4
0
3
External Alarm Kind
0: Fault Memory store/No output of
External Alarm
1: Fault Memory store/External Alarm is
MN alarm
2: Fault Memory store/External Alarm is
MJ alarm
3: No Fault Memory store/No External
Alarm output
053 SIP trunk returned to normal condition
101 Power failure returned to normal condition
103 DTI line returned to normal condition
105 SV8300 Blade returned to normal condi-
tion
111 Communication error restoration between
active CPU and stand by CPU
[8300R4 software required]
113 Expansion Chassis (2U) returned to normal
condition
[8300R3 software required]
External Alarm Kind
0: Fault Memory store/No output of
External Alarm
1: Fault Memory store/External Alarm is
MN alarm
2: Fault Memory store/External Alarm is
MJ alarm
3: Fault Memory store/No External
Alarm output
~
CM42
E
APRIL/16/2010