Chapter 1 MAINTENANCE SERVICES
1-11 NWA-033627-001 Rev.4.0
95ch1001.fm
FAULT MESSAGE
NOTE 1: Even if the external alarm is set as MN or MJ alarm for system reset (1st data=01), no alarm
is output in the case of Power On, Reset key operated, reset from the PCPro/CAT, and reset by
CPU SENSE switch selection.
NOTE 2: The External Alarm Kind for “Number of lockout stations was more than predetermined num-
ber” is fixed as MN. In the case of this office data, even if the 2nd data is set to 0/1/2/3, it simply
means the fault information is to be registered into Fault Memory. In this case, External Alarm
Kind cannot be changed.
NOTE 3: The fault information of the fault kind No, 02C/03C is also registered to the CPU blade when
the OAI fault occurs/the OAI fault is restored. The OAI fault contents that are registered to the
CPU blade as follows.
Fault Kind 02C (LAN application fault occurrence)
(a) ABOUT/RLRQ (U-ABOUT/RLRQ received)
(b) Fault detection by health check (health check IP T.O)
Fault Kind 03C (LAN application returned to normal condition)
(a) Association is established (AARQ received)
DESCRIPTION DATA
Provide registering fault information when
long call duration of trunk call occurs.
(1)
(2)
Y=286
00-63: Trunk Route No.
0 : Not provided
1: To provide
E
CM35
END
APRIL/16/2010