EasyManua.ls Logo

Necta Snakky Max - Statistics

Necta Snakky Max
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
© by NECTA VENDING SOLUTIONS SpA 0407 239 - 00
STATISTICS
Data on the machine operations is stored in both general
counters and relative counters, which can be reset without
losing total data.
PRINT
Connect an RS232 serial printer having a Baud rate of
9600, 8 data bit, no parity, 1 stop bit to the serial port
located on the push button board to print all of the
statistics, and namely:
Total
1 - counter by single selection;
2 - counter by time bands;
3 - failure counter;
4 - coin mechanism data;
5 - photocell errors;
6 - motor errors;
Relative
1 - counter by single selection;
2 - counter by time bands;
3 - failure counter;
4 - coin mechanism data;
5 - photocell errors;
6 - motor errors;
The hardcopy printout will also contain the machine infor-
mation, and namely:
- date/time of print
- machine name
- software version
- operator code
- machine code
- Installation date.
To connect the printer, do as follows:
- press the confirm print button “ ”, displaying the
message “Confirm?”;
- connect the printer before confirming;
- press the confirm button “ ” to start printing.
DISPLAY
When pressing the confirm button “ ” the data described
in the paragraph “Printing the statistics” is sequentially
displayed.
RESETTING THE STATISTICS
Statistics can be reset for counters globally (all types of
data) or selectively for:
Total
- selections
- failures
- coin mechanism data
- photocell errors;
- motor errors;
Relative
- selections
- failures
- coin mechanism data
- photocell errors;
- motor errors;
Press the confirm button “ ”, and the message “Con-
firm?” starts blinking.
Press the confirm button “ ”, the message “Working” is
displayed for a few seconds and all statistics are reset.
N.B.: when resetting the total statistics also the relative
statistics are reset.
BDV protocol Audit
The information regarding the coin mechanism indicates
the actual currency of:
Audit 1 Money in the tubes
Money present in the change tube that moment
Audit 2 Money to the tubes
Money sent to the change tubes
Audit 3 Money to the box
Money sent to the coin box
Audit 4 Return of change
Total money returned
Audit 5 Dispensed money
Total money dispensed manually
Audit 6 Excess
Excess money. Extra amounts paid by the customer that
were not returned (in the event there was no money
available for return)
Audit 7 Total sales
Total value of sales
Audit 8 Exact change
Value of sales in the “no change” condition.
Audit 9 Mixed dispensing
Total value of dispensing paid differently; for example also
other types of payment (C.P.C., token).
Audit 10 Manual filling
Money inserted in the coin mechanism through the manual
filling function.

Related product manuals