4
© by NECTA VENDING SOLUTIONS SpA 0407 239 - 00
TECHNICAL SPECIFICATIONS
Power supply voltage 230 V~
Power supply frequency 50 Hz
Absorbed power 560 W
Max. operating conditions:
Ambient temperature 32 °C
Relative humidity 65 %
Refrigeration system:
Compressor’s refrigeration output 620 W
Fan-forced evaporator
Programmable defrosting cycle
DIMENSIONS
Height 1830 mm
Width 740 mm
Depth 855 mm
Overall depth with door open 1350 mm
Weight 225 Kg
PAYMENT SYSTEM
The machine is supplied with all electrical prearrangement
for systems with Executive, BDV and MDB protocol, as
well as for installation of 24 V DC validators.
Beside the coin mechanism housing, suitable space is
provided for the installation (optional) of the most widely
used payment systems.
SALES PRICES
A different programmable price can be set for each single
selection.
COIN BOX
Cover and lock are available as an optional feature.
CONTROLS AND SAFETY DEVICES
- Payment system compartment switch
- Timeout for power supply to dispensing motors
- Compressor overheating protection
- Line fuses
- Fuses on transformer primary and secondary windings
ACCESSORIES
A wide range of accessories can be installed on the
machine, to vary its performance.
The installation kits are supplied with their own installation
and test instructions, which must be strictly observed to
ensure the machine safety.
Installation and the following testing operations must
be carried out exclusively by personnel who have a
specific knowledge of the machine functions from a
point of view of electrical safety and health regula-
tions.
POWER CONSUMPTION
The machine power consumption depends on many fac-
tors, such as temperature and ventilation of the room
where it is installed, temperature of loaded products,
internal temperature of the refrigerated box.
Under average conditions, and namely:
- Ambient temperature: °C 20
- Refrigerated box temperature: °C 5
- temperature of loaded products
(machine completely empty) °C 20
the following power consumption levels resulted:
- Hourly stand-by power consumption Wh 266
The above power consumption calculated from average
data should only be taken as an indication.
Fig. 3