23
© by NECTA VENDING SOLUTIONS SpA 0407 239 - 00
MDB protocol Audit
Audit 1 Money in the tubes
Money present in the change tubes that moment
Audit 2 Money to the tubes
Money sent to the change tubes
Audit 3 Money to the box
Money sent to the coin box
Audit 4 Change return
Total money returned
Audit 5 Excess
Excess money. Extra amounts paid by the customer that
were not returned (in the event there was no money
available for return)
Audit 6 Release of tubes
Value of coins dispensed with the “Tubes control” function
Audit 7 Filling tubes
Value of money cashed with the manual loading function
Audit 8 Cash sales
Value of total sales with cash money (coins + bills)
Audit 9 Cashed bills
Value of cashed bills
Aud. 10Charge key
Value of money changed into the key
Aud. 11Sales with key
Value of money cashed for dispensing with key
Audit. 12 Money dispensed manually
Value of coins dispensed manually with the dispensing
buttons on the coin mechanism.
TEST
SELECTIONS
This function is used to simulate the normal dispensing of
products without inserting any money.
Check the functioning of the motor rotation by pressing the
selection buttons.
MOTOR TEST
It activates all motors in a sequence.
AUTOTEST
A function to check, in a semiautomatic manner, the
correct operation of some devices is implemented in the
software.
Some checks occur automatically, others need the manual
operation of the monitored component; button “ ” is
pressed to go to the next check.
The monitored devices are:
“Keypad”
Press the button requested on the display; if it works
correctly the request for the next button is presented.
“Temperature”
The value of temperature detected by the probe is dis-
played.
In the event of disconnection the value -11.0 is displayed.
In the event of a short-circuit the value 41.0 is displayed.
“ ” to advance.
“Buzzer”
A series of sounds is emitted.
“Compressor”
The compressor is activated/deactivated using the “ ”
and “ ” buttons.
“Selections”
All selections are activated in a sequence.
“Coin mechanisms”
Checking that communication with the coin mechanism
takes place correctly and which validator lines are set as
being active.
“Photocells”
If the product detection device is present, the light beam
reading and interruption are checked.
“Disp compt lock”
If the device for locking the dispensing compartment
opening, use the “ ” and “ ” buttons to lock and unlock the
compartment opening.
“Direct keypad”
If fitted on the machine, the 5 buttons are checked
sequentially.
Press the button requested on the display; if it works