35
Filler menu - Summary
CONFIRM DATA/
CONFIRM FUNCTION
DELETE DATA/
EXIT FUNCTION
PREVIOUS FUNCTION/
DECREASE DATA UNIT (-
1)
NEXT FUNCTION/
INCREASE DATA UNIT (+1)
DIRECT ACCESS TO CHANGE
PRICE OF TIME BAND 0
Confirm?
Coin mech test
Failure list
Coin mech test
WITH EXECUTIVE, BDV OR
MDB COIN MECHANISMS
If the coin mechanism
communicates it displays "OK"
ALTERNATIVELY
WITH A VALIDATOR
Confirm?
Coin mech test Coin mech test Coin mech test
Valid. line #
Line two remains for
approximately 2 seconds
Confirm?
Photocell test
WITH PHOTOCELLS
DISCONNECTED
ALTERNATIVELY
Photocell test
Absent
Confirm?
Photocell test
Failure list
Photocell test
If the light beam is interrupted within
2.5 seconds it displays "OK"
or
Error no product
If a failure is present:
Error after dispensing
Error before dispensing
WITH PHOTOCELLS