© by NECTA VENDING SOLUTIONS SpA
39
Technician menu - Summary
0407 239 - 00
CONFIRM DATA/
CONFIRM FUNCTION
DELETE DATA/
EXIT FUNCTION
PREVIOUS FUNCTION/
DECREASE DATA UNIT (-1)
NEXT FUNCTION/
INCREASE DATA UNIT (+1)
TECH >2.1.1.3
Time bands
X + 1
X - 1
TECH >2.1.1.3.1
Set date and time
Date: dd/mm/yy d#
Year
##
X + 1
X - 1
Time: hh/mm/ss
Time:
##
X + 1
X - 1
TECH >2.1.1.3.2
Time band 1-4
Start: hh/mm
End: hh/
##
CLOCK
When confirming the blinking
values, day, month, year and
week day are entered one after
the other. When confirming the
week day hour and minutes are
displayed, that can then be
changed and confirmed.
TIME BANDS
When confirming the blinking
values, hour and minute for
start and end of time band are
entered one after the other.
When start and end of time
band are set to 00.00 the bands
are not activated.