VP1006-200PM-00 OEM ISO Reader Manual version 2.6 / Page 11
7 Trouble shooting
Errors / malfunctioning is indicated by the indicator LED’s or the display.
Error by indicator LED
Indicator LED’s are normally green or switched off. A red or orange indicator LED means normally
there is something not ok. See Appendix D for the explanation of the different colors.
Errors indicated at menu option “dE”
In menu option “dE” it is possible to see actual error codes. When entering the display menu option
“dE” the errors code will be shown and the error will be cleared. If the error is not cleared it means
there is still an error. There can be more than one error. Further errors are displayed one after another
with a short delay between each code.
“dE” code on the display
Description
00
No errors
01
Max time for motor exceeded
02
Max motor current error
03
-
04
-
05
Outputs switched off due to high motor current
06
Software switched off due to current and time
07
Output switched off due to current, time and also output active
08
Input of motor output seen X times while motor is not active
09
Motor 1 error
10
Motor 2 error
11
Motor 3 error
12
Motor 4 error
13
Vout overload
14
Output 5 shut off due to overload
15
Output 6 shut off due to overload
16
Software switched off due to max current and time
17
CANbus over voltage
18
Voltage to next module switched off
Identification performance and disturbance
Identification performance can be reduced by disturbance caused by variable-frequency drives used
for ventilation, milk pumps, vacuum pumps, etc. Also ballasts used for fluorescent tube lighting may
interfere. If there is interference one can locate the source by switching off all the equipment on a farm
and then switch them on again one by one. Most of the time when a variable-frequency drive is
causing a problem it is due to bad installation or without the mandatory main filters.
8 Maintenance, cleaning and disposal
Maintenance
No regular maintenance required.
Software update
A VP1006 is equipped with software to activate inputs and outputs, display / push button and a motor
safeguard. This software is called firmware. During manufacturing the firmware is programmed and
ready for use. In case of an update it is possible to download new firmware thru the CAN-bus. In the
Velos system the web browser interface of the VPU (VP8001) is used to handle this. For more details
about downloading new firmware see also the manual of the VPU (VP8001).
Cleaning
A VP1006 must be installed in a suitable housing (V-box) so cleaning of the VP1006 is not required.
Disposal
Discard according to the regulations prevailing at the time of disposal