VP1006-200PM-00 OEM ISO Reader Manual version 2.6 / Page 12
Appendix A: Specifications / CE
143 x 120 x 68 mm LxWxH (excluding mounting rail) Weight: ± 360 gr
CAN-bus communication 125 kBit
Input voltage 25 VDC, +20% -20%
Min power consumption 300 mA with antenna switched on
Maximum power consumption 2,5 A
Protected against reverse connection power supply
Downloadable by the CAN network
Reading inputs, analog (0-40V) and digital. Suitable for NPN and PNP sensors.
Max. 2.5 Amp by current limiter, short-circuiting protected Motor safe-guard (after 25
sec)
800 µH. Different types possible.
Synchronisation according to ISO 11785
Temperature: Operating: -10 – 50 °C, Storage: -25 – 70 °C
Relative humidity: 10 – 93% non condensing
Maximum noise level: 10 dBµA/m quasi peak, according CISPR 16-1-1
Conducted noise: according EN55022
IP 30. When installed in V-box IP 65 (cover and cables installed correctly !)
Always use a NEDAP power supply. The Nedap guarantee-regulations are only valid when is installed as
indicated in this manual. Install data cables at a safe distance from (high) powered cables
For more detailed information contact your local Nedap supplier or check the internet site.