VP1006-200PM-00 OEM ISO Reader Manual version 2.6 / Page 22
Appendix I: Neutrodynisation unit between two antennas
Two large antennas can have coupling with antenna fields. Result : tag is identified in both antennas. A
solution is to install a neutrodynisation unit.
Required equipment:
- Readers with the option Neutro in the HF menu
- A neutrodynisation unit
- Coax cable, specification RG58
- Cable between the readers to connect SYNC OUT and SYNC IN
shield
core
shield
core
READER A
READER B
Display value
(0- 99)
Turn to max display value
Neutrodynisation adjustment
1. Set reader A in neutro transmit mode
(HF menu option nc - nt)
2. Set reader B in neutro receive mode
(HF menu option nc - nr)
3. Turn the wheels apart to the highest
display value at reader B
The display value and wheel distance
apart can vary. Low display value means
usually low coupling.
COAX RG58
COAX RG58
COAX RG58
COAX RG58
Neutrodynisation unit