VP1006-200PM-00 OEM ISO Reader Manual version 2.6 / Page 15
Appendix C: Overview display menu
DISPLAY ADDRESS
Shows the actual address
SET ADDRESS
Change the address
ADJUST ANTENNA
Antenna tuning will be shown by output 6 (lamp)
ANTENNA POWER
Min/max 10 / 99. Normally set to 99. Possible to set a lower value.
ANTENNA SENSITIVITY SQUELCH
Min/max 9 / 0. Normally set to 0. Possible to set a lower value.
Neutrodynisation adjustment
Nt = Neutro transmit Nr = neutro receive
DISPLAY ERROR CLEAR ERROR
Shows error code and error clearing after showing.
TEST ALL OUTPUTS
All outputs are switched on one by one. Test results are shown on the display
TEST MOTOR OUTPUT
o1 … o4
TEST OUTPUT
L1 … L6
TEST INPUT
I1 … i6
SIGNAL LEVEL FDX
Shows signal level measured by the FDX receiver
SIGNAL LEVEL HDX
Shows signal level measured by the HDX receiver
TEST IDENTIFICATION
Shows last 2 digits of a tag number
COMMUNICATION CHANNEL
Enter a number to set the right settings (see table next page)
COMMUNICATION PROTOCOL
Enter a number to set the right settings (see table next page)
Press button until blinking
Short press on button
To leave menu:
Press button until display goes blank