10.3.15
E015 Warning - Near Maximum Welding Output
Capacity
Fatal, meaning you have to power down to continue welding
No
Acknowledge, meaning the error will exist as long as the unit is
powered on.
(Note, welding can continue while the error exists)
No
Description:
The unit is at or above 95% of the power the unit is capable
of delivering (voltage x
current), it will display this warning. When this
warning is being displayed, there is a
possibility that the weld current
will start to sag. As shown in the picture below, if the
demanded voltage for any given current is above the diagonal “power unit capability”
line, the current will naturally drop in accordance with the
capability line. For best
reliability, stay within the ‘Linear Area’.
To achieve this, reducing the voltage is the most practical. Reduce weld
cable length,
increase weld cable size, and\or reduce lift. Another way
is to reduce weld current if
the application allows less current, more time.
This Warning can be disabled using F54