EasyManua.ls Logo

Nelson N800iTM - Page 135

Nelson N800iTM
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tucker GmbH, Mail / Post: Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
128
10.3.16
E016 Warning - Check Weld Cables and Connectors -
Press lock to clear
Fatal, meaning you have to power down to continue welding
No
Acknowledge, meaning the error will exist as long as the unit is
powered on.
(Note, welding can continue while the error exists)
Yes
Description:
If a cable resistance target was saved using F55 and F56,
upon each weld, the unit
will measure the weld cable resistance. If for
any weld the resistance is outside of the
tolerance windo set by F56, this
warning will be displayed. Press the ‘lock’ key to
clear the eroor while
viewing the error in F1 (error display).
To remedy, periodically tighten connectors and inspect cables for any
cause for
increased resistance. Cables will naturally increase as weld
current heats them. If a
new cable resistance target is required, save it
in F55 following a weld. A new target
is required when added or remo-
ving cables.
Connectors
E016

Table of Contents

Related product manuals