Tucker GmbH, Mail / Post: Max-Eyth-Str.1, 35394 Gießen, Germany
Stud welding unit N800i
As of 24.08.2021
Manual part number: BE 1227
92
Error Number
Error Display
What this really means
Fatal meaning you
have to power down
to reset. Otherwise,
you weld again to
reset.
Likely problem
E018
WARNING ‐ DROP
TIME IS TOO LONG
FOR SHORT CYCLE
The configurations of the
drop time(F31) and the front
panel time make it such that
the pilot arc supply must be
on for more than 40ms. The
maximum time the pilot arc
will stay on is 40ms, so it is
possible the arc will go out
before the main arc starts.
For consistent welds, recon‐
figure the drop time and\or
front panel time to satisfy
the equation
F code \ Front panel configuration
E019
ADDITIONAL WAR
NING WAIT ON UP‐
PER DISPLAY AND
CYCLE OR CAP ON
LOWER DISPLAY
1.
Weld duty cycle is excee‐
ded
2.
Switch board out of calib‐
ration
3.
Switch board malfunction
X
1 of 3 reasons.
‐See troubleshooting‐