EasyManua.ls Logo

Nescafe C70 - 12 Remove Electronic Module (Main PCB)

Nescafe C70
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 1.0 en Prodigio service manual
59
REPAIRS
7.4.12 Remove electronic module (main PCB)
Remove isolation cover (29) from pump (30).
Unplug both Faston receptacles from pump terminal (see below).
Pull off low pressure tube (32) from flowmeter (22) - see below.
See detail: Press in locking wedge on electronic front cover (81) with a screwdriver
and pull out electronic module.
Unplug cable connectors from electronic module (if not already done):
- DC motor connector (38),
- thermoblock (35): NTC / Triac signal connector, 2 Faston receptacles
- flat cable (50) to MMI board (3).
29
81
30
For pump removal,
refer to page 63.
81
50
22
38
35
32
30
48

Table of Contents