Version 1.0 en Prodigio service manual
59
REPAIRS
7.4.12 Remove electronic module (main PCB)
• Remove isolation cover (29) from pump (30).
• Unplug both Faston receptacles from pump terminal (see below).
• Pull off low pressure tube (32) from flowmeter (22) - see below.
• See detail: Press in locking wedge on electronic front cover (81) with a screwdriver
and pull out electronic module.
• Unplug cable connectors from electronic module (if not already done):
- DC motor connector (38),
- thermoblock (35): NTC / Triac signal connector, 2 Faston receptacles
- flat cable (50) to MMI board (3).