OPERATION
4.3 Machine modes
4.3.1 Machine modes of coffee machine
This table helps to understand the operating modes of the Prodigio coffee machine:
This table also con-
tains the keying
sequences for
- volume programming
- descaling
- water system emptying
- resetting
- changing the automatic
switch off time.
Machine mode Enter mode Actions Exit mode
1 Heat up mode
Every time after switch-
ing on machine
Heat up thermoblock to
ready temperature 90
°C within 30 sec with-
out overshooting target
temperature
e.g. switching off
machine
2 Self test mode
Every time after switch-
ing on machine
Tests:
NTC short circuit
NTC connected
Checks if thermo-
block reaches ready
temperature within
2 min after switch on
e.g. switching off
machine
3 Ready mode
After heat up and self
test mode was ok
After brewing or
volume brewing
coffee
After reset mode
After leaving
descaling mode
Keep thermoblock
temperature at 90 °C
e.g. switching off
machine
4a Brewing mode
4b Volume brewing
mode (program-
ming cup size)
Brewing mode:
Press and release
any coffee button
Programming mode:
Open and close the
slider
Press and hold any
coffee button for
more than 3 sec
Press and release
any coffee button
when machine is in
brewing mode or
automatic exit given
by the flowmeter
Release corre-
sponding coffee
button when
machine is in
programming mode
Switch off machine
5 Descaling mode
Switch on the
machine and wait
until ready
Press and hold all
three coffee buttons
for at least 6 sec until
confirmation with a
beep.
Regulate tempera-
ture to 70 °C (after
pump was started)
Stop and start pump
with any coffee
button, no volume
brewing in descaling
mode
Press and hold all
three coffee buttons
for at least 6 sec until
confirmation with a
beep.
Note: When machine is
switched off during any
descaling mode, then it
goes to descaling
mode ready state after