/------------------------/
/ Output /
/------------------------/
Wait...........: -<--
Fault..........: -
Permanent fault: -
N/A............: 4
N/A............: 3
N/A............: -
N/A............: -
Input sensor...: 1
Press [Esc] to quit
With this menu is possibile to associate a digital output of the installed sensors to one or more
events of the UPS. The output will be closed when the associated event happens.
Press ENTER to select the output.
The identification number is the same which is associated to the sensor during
installation.
The following table describes the meaning of the events. These can vary depending on the PVI
connected.
The inverter is waiting the connection to the grid
The inverter is not connected to the grid
The “Input sensor” event allows to associate a digital output with the digital input of the Digital I/O &
Temperature sensor which is installed with the lowest identification number (the first that was
detected during configuration). The state of the input (open/closed) is reported to the output of
the selected sensor.