7-MAINTENANCE
RollOverProtectiveStructure(ROPS)frame-Check
NOTE:InspecttheRollOverProtectiveStructure(ROPS)
aftertherst50hoursofoperation.Followingtheinitial
inspection,theROPSshouldbecheckedafterevery250
hoursofoperationoreverysixmonths,whichevercomes
rst.
1.CheckthetorqueoftheRollOverProtectiveStructure
(ROPS)bottomportionmountingbolts(1).Torquethe
M12,boltsto76N·m(56lbft)ifnecessary.
NHIL17CT00457AA1
Seatbeltmountingbolts
1.Inspecttheoperator'sseatandthemountingpartsfor
theseatbelt(2).
2.Tightenthebolts(1)to61N·m(45lbft).
3.Replaceanypartsthatshowwearordamage.