Step 4: How much to collect
This step specifies the sampling frequency and sampling duration for the gathering
configuration and is based upon the API function
EventExtendedConfigurationActionSet(GatheringRun, Nb of points, Divisor, 0, 0).
Refer to Features Manual for more information.
1. Click on MODIFY to specify the frequency at which data is collected and the
duration of the data sampling. The maximum sampling frequency is at the XPS
servo rate. Example: Data will be collected at 2 kHz frequency for a total of 2
minutes.
Step 5: Save Configuration
1. Click on SAVE CONFIGURATION to save the gathering configuration.
Example: Gathering starts when the constant velocity state is reached for positioner
Group1.Pos. Once the trigger event occurs, current position values will be collected
for positioner Group1.Pos. Data will be collected at 2 kHz frequency for a total of 2
minutes.