CMS100 Product Manual, Issue 8
www.nexo.com Page 21
3.4 The menu arrangement
Enter
password
Parameter
List(PS)
DIF
SP
CF
Andsoon...
Setbutton-presstoselect
Defrostbutton-presstoreturn
Upbutton-presstoscrollup
Downbutton-presstoscrolldown
TestMenu
(tSt)
FaultList
(FLt)
HalfReset
(Hr)
FullReset
(Fr)
DataDump
(ddP)
EnterFull
ResetPassword
RelayTest
(rEL)
Compressor
(CP)
Light
(LIt)
Fan
(FAn)
Buzzer
(BUZ)
All
(ALL)
Analogue
Test(AnA)
Infrared
Test(Plr)
-usetoincreasevalue
-usetodecreasevalue
Behind each of the sub-menu headings there is a list for further options:
` Selecting PS enters the parameter list, and from here parameters and their values can be
viewed, checked and amended as required.
` Selecting t St - the test menu - allows the three test routines to be carried out. Unlike previous
versions of the ems; it is now possible to simply carry out the test required - without having to
perform all three.
` Selecting Hr - half re-set - will allow a half reset to be performed which will wipe the learning
matrix, allowing the controller to re-learn outlet opening and closing times.
Note
The full reset is to be performed by Elstat personnel.
The data dump is for Elstat use only for testing and development purposes.