F2040-12Model
Air-water
Exhaust-water
Brine-water
Water-water
Type of heat pump
Yes No
Low-temperature heat pump
Yes No
Integrated immersion heater for additional heat
Yes No
Heat pump combination heater
Average Cold Warm
Climate
Average (55 °C) Low (35 °C)
Temperature application
EN14825 / EN14511 / EN12102Applied standards
%132ƞ
s
Seasonal space heating energy efficiencykW10PratedRated heat output
Declared coefficient of performance for space heating at part load and at outdoor
temperature Tj
Declared capacity for space heating at part load and at outdoor temperature Tj
-1.99COPdTj = -7 °CkW8.9PdhTj = -7 °C
-3.22COPdTj = +2 °CkW5.5PdhTj = +2 °C
-4.61COPdTj = +7 °CkW3.5PdhTj = +7 °C
-6.25COPdTj = +12 °CkW5.0PdhTj = +12 °C
-1.90COPdTj = bivkW9.2PdhTj = biv
-1.92COPdTj = TOLkW8.1PdhTj = TOL
-COPdTj = -15 °C (if TOL < -20 °C)kWPdhTj = -15 °C (if TOL < -20 °C)
°C-10TOLMin. outdoor air temperature°C-8T
biv
Bivalent temperature
-COPcycCycling interval efficiencykWPcychCycling interval capacity
°C58WTOLMax supply temperature-0.98CdhDegradation coefficient
Additional heatPower consumption in modes other than active mode
kW1.9PsupRated heat outputkW0.002P
OFF
Off mode
kW0.014P
TO
Thermostat-off mode
ElectricType of energy inputkW0.015P
SB
Standby mode
kW0.035P
CK
Crankcase heater mode
Other items
m
3
/h4,380Rated airflow (air-water)VariableCapacity control
m
3
/h0.86Nominal heating medium flowdB35 / 57L
WA
Sound power level, indoors/outdoors
m
3
/hBrine flow brine-water or water-water heat pumpskWh6,136Q
HE
Annual energy consumption
NIBE Energy Systems Box 14 Hannabadsvägen 5 285 21 Markaryd SwedenContact information
NIBE F2040Chapter 12 | Technical data74

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F2040 Series and is the answer not in the manual?

Nibe F2040 Series Specifications

General IconGeneral
SeriesF2040
RefrigerantR410A
COPUp to 5.0 (depending on model and operating conditions)
Sound Power Level Indoor UnitN/A (Requires separate indoor unit)
Operating Temperature Range Cooling+10°C to +43°C
Dimensions Indoor Unit (HxWxD)N/A (Requires separate indoor unit)
TypeAir Source Heat Pump