EasyManuals Logo

Nibe F2040 Series User Manual

Nibe F2040 Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
F2040-16Model
Air-water
Exhaust-water
Brine-water
Water-water
Type of heat pump
Yes No
Low-temperature heat pump
Yes No
Integrated immersion heater for additional heat
Yes No
Heat pump combination heater
Average Cold Warm
Climate
Average (55 °C) Low (35 °C)
Temperature application
EN14825 / EN14511 / EN12102Applied standards
%134ƞ
s
Seasonal space heating energy efficiencykW14PratedRated heat output
Declared coefficient of performance for space heating at part load and at outdoor
temperature Tj
Declared capacity for space heating at part load and at outdoor temperature Tj
-2.01COPdTj = -7 °CkW12.5PdhTj = -7 °C
-3.29COPdTj = +2 °CkW7.6PdhTj = +2 °C
-4.68COPdTj = +7 °CkW4.9PdhTj = +7 °C
-6.51COPdTj = +12 °CkW6.8PdhTj = +12 °C
-1.95COPdTj = bivkW12.7PdhTj = biv
-1.95COPdTj = TOLkW11.0PdhTj = TOL
-COPdTj = -15 °C (if TOL < -20 °C)kWPdhTj = -15 °C (if TOL < -20 °C)
°C-10TOLMin. outdoor air temperature°C-8T
biv
Bivalent temperature
-COPcycCycling interval efficiencykWPcychCycling interval capacity
°C58WTOLMax supply temperature-0.98CdhDegradation coefficient
Additional heatPower consumption in modes other than active mode
kW3.0PsupRated heat outputkW0.002P
OFF
Off mode
kW0.016P
TO
Thermostat-off mode
ElectricType of energy inputkW0.015P
SB
Standby mode
kW0.035P
CK
Crankcase heater mode
Other items
m
3
/h6,000Rated airflow (air-water)VariableCapacity control
m
3
/h1.21Nominal heating medium flowdB35 / 61L
WA
Sound power level, indoors/outdoors
m
3
/hBrine flow brine-water or water-water heat pumpskWh8,431Q
HE
Annual energy consumption
NIBE Energy Systems Box 14 Hannabadsvägen 5 285 21 Markaryd SwedenContact information
75Chapter 12 | Technical dataNIBE F2040

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F2040 Series and is the answer not in the manual?

Nibe F2040 Series Specifications

General IconGeneral
SeriesF2040
RefrigerantR410A
COPUp to 5.0 (depending on model and operating conditions)
Sound Power Level Indoor UnitN/A (Requires separate indoor unit)
Operating Temperature Range Cooling+10°C to +43°C
Dimensions Indoor Unit (HxWxD)N/A (Requires separate indoor unit)
TypeAir Source Heat Pump

Related product manuals