TITAN 912L Linear Actuator
Installation Reference Manual
77
2
MOUNT ACTUATOR TO PIVOT ARM
FIG-2A: INSTALLING ACTUATOR TO PIVOT ARM
FIG-2B: LEVEL ACTUATOR
(GATE OPEN)
FIG-2C: LEVEL ACTUATOR
(GATE CLOSED)
1. Mount actuator to pivot arm as shown in FIG-2A using 1/2” bolt and lock nut. Tighten until secure.
2. Use bubble level to ensure actuator is level and plumb in both open and closed positions.
1/2”x 3.5” BOLT
ACTUATOR
1/2”LOCK NUT
PIVOT ARM
PIVOT ARM
CABLE LOOP
LEVEL
LEVEL
LEVEL
LEVEL
ACTUATOR
IMPORTANT!
When using a bubble level to ensure pivot arm/
actuator are plumb and level, check in both open
and close positions per FIG-2B and 2C.
Ensure that actuator mounting hardware is tight
enough to prevent movement, vibration, wobble,
or shifting when the actuator is in operation.
Note cable loop (FIG-2C) to allow strain relief for
cable during actuator0 movement.
www.ApolloGateOpeners.com | (800) 878-7829 | Sales@ApolloGateOpeners.com