Page #29 background image
S2 / S3
09/2017
11
C343
GB
WARNING!
In particular, on Class H vacuum cleaners, the ltering
eciency of the vacuum cleaner must be checked at
least once a year, or more often if required by national
legislation. The test method for checking the ltering
eciency of the vacuum cleaner is indicated in
standard EN 60335-2-69, par. 22.AA.201.2.
If the test isn’t passed, it must be repeated after the
class H lter has been changed.
WARNING!
This vacuum cleaner can vacuum dust hazardous for
the health. The procedures for servicing and emptying
the vacuum cleaner including removing the dust
container, must only be performed by specialised
personnel wearing protective clothing. Do not use
without the complete lter system in place.
Primary and absolute lter disassembly
and replacement
WARNING!
When the vacuum cleaner is used to vacuum
hazardous substances, the lters become
contaminated, therefore:
work with care and avoid spilling the vacuumed
dust and/or material;
place the disassembled and/or replaced lter in a
sealed plastic bag;
close the bag hermetically;
dispose of the lter in accordance with the laws
in force.
WARNING!
Filter replacement is a serious matter. The lter must
be replaced with one of identical characteristics,
ltering surface and category.
Otherwise the vacuum cleaner will not operate
correctly.
Primary lter replacement
Figure 14
1. Vacuuming unit
2. Locking lever
3. Filter cage
4. Primary lter
5. Filter shaker housing
WARNING!
Check the vacuum cleaner class (L, M, H).
WARNING!
Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
Before proceeding with these operations, turn the
vacuum cleaner o and disconnect the plug from the
power socket.
Use lever (2) to release vacuum unit (1) then pull it up
and out of the vacuum cleaner.
Remove the lter cage from the vacuum cleaner.
Remove the old lter by releasing the xing clips.
Fit the new lter and secure it in the cage with special
clamps.
Dispose of the old lter according to the laws in force.
Replacing a primary lter with automatic lter shaker
WARNING!
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
After replacing the lter in the cage (3), install it in the
container again.
Reassemble vacuum unit (1) making sure lter cage (3)
ts into shaped housing (5) of the lter shaker.
Turn the power switch on and the vacuum unit will self-
centre automatically.
Use locking lever (2) to lock the vacuum unit in place.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance S2 L and is the answer not in the manual?

Nilfisk-Advance S2 L Specifications

General IconGeneral
BrandNilfisk-Advance
ModelS2 L
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals