C343
12
09/2017
S2 / S3
GB
Replacing a primary lter with manual lter shaker
Figure 15
1. Manual lter shaker knob
2. Vacuuming unit
3. Locking lever
4. Filter cage
5. Filter shaker housing
WARNING!
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
■ After having replaced and tted the lter in the cage,
insert lter shaker cage (4) in the shaped seat (5) of the
lter shaker.
■ Position the manual lter shaker knob (1) in the middle.
■ Reassemble vacuum unit (2) complete with cage and
lter, in the vacuum container.
■ Check the lter shaker works properly and if necessary
adjust the position of the lter cage by turning the
vacuum unit.
■ Use locking lever (3) to lock the vacuum unit in place.
If necessary contact the manufacturer’s Service Centre.
HEPA lter replacement
Version for dust harmful for the health: Class H
WARNING!
Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
WARNING!
Do not use the Class H lter again after having
removed it from the vacuum cleaner.
Figure 16
1. Vacuuming unit
2. Locking lever
3. Safety bolt
4. Absolute lter lock ring
5. Absolute lter disc
6. Absolute lter
WARNING!
Reassemble with care to avoid trapping your hands
between the vacuum unit and the container. Use
gloves that provide protection against mechanical
risks (EN 388) with a level of protection CAT. II.
Before proceeding with these operations, turn the vacuum
cleaner o and disconnect the plug from the power socket.
■ Unlock the safety bolt (3).
■ Use lever (2) to release vacuum unit (1) then pull it up
and out of the vacuum cleaner.
■ Unscrew ring (4).
■ Pull out disc (5) and absolute lter (6).
■ Place absolute lter (6) in a plastic bag, close the bag
hermetically and dispose of the lter in accordance with
the laws in force.
■ Insert a new lter (6) with the same ltering
characteristics as the removed one.
■ Lock the absolute lter with disc (5) and tighten ring (4).
■ Replace vacuum unit (1).
■ Fix the vacuum unit in place with lever (2) and lock safety
bolt (3) again.