5
ATTIX 30-50 H/M
CAUTION
Damage due to unsuitable mains voltage.
The appliance can be damaged as a result of being connected
to an unsuitable mains voltage.
Ensure that the voltage shown on the rating plate corre-1.
sponds to the voltage of the local mains power supply.
Picking up liquids
CAUTION
Picking up liquids.
Do not pick up flammable liquids.
Before liquids are picked up, always remove the filter bag/1.
waste bag and check that the float
1)
or the water level lim-
it
1)
works properly.
The use of a separate filter element or filter screen is rec-2.
ommended.
If foam appears, stop work immediately and empty the 3.
tank.
Hazardous materials
WARNING
Hazardous materials.
Vacuuming up hazardous materials can lead to serious or
even fatal injuries
The following materials must not be picked up by the 1.
vacuum cleaner:
hot materials (burning cigarettes, hot ash, etc.) -
flammable, explosive, aggressive liquids (e.g. petrol, -
solvents, acids, alkalis, etc.)
flammable, explosive dust (e.g. magnesium or alumin- -
ium dust, etc.)
Using the vacuum cleaner for
asbestos abatement work
WARNING
To pick up materials containing asbestos:
ATTIX 30-XH and ATTIX 50-XH1. can be used for picking
up asbestos.
The hose diameter and the setting for the suction hose 2.
diameter must be the same.
Use the closable plastic sack to ensure dust-free transport
of the vacuum cleaner and contaminated parts (hose, hand
pipe, nozzles, etc.). Once the asbestos vacuum cleaner
has been used in an exclusion area as defined
in TRGS 519, it should no longer be used in so-called
“white” areas. Exceptions are only permitted if the asbestos
cleaner has previously been completely decontaminated
by a specialist as specified in TRGS 519 No. 2.7
(e.g. not only the outer case but also, for example, the
cooling air rooms, the installation rooms for electrical
supplies, the supplies themselves, etc.). A written report
must be made by a specialist and signed by him.
When dust removers are used, the rate at which air is
exchanged in the room must be adequate if the exhaust
air from the vacuum cleaner is blown into the room (please
observe regulations valid in your country). If using exhaust
air collector, use a hose with a length of max. 4 m and a
nominal diameter of max. 50mm.
1)