© 2005-2016 Nira Control AB 6
each wire in the harness is marked every 70 mm (~3”) with its function in
clear text. This makes it possible to cut the wire to desired length and still
read its function.
1.1.3 NIRA rk
NIRA rk is the calibration software that allows you to setup and configure a
large number of parameters in NIRA i7x. It is designed to run on a PC using
the Windows operating system and communicates with NIRA i7x via a Kvase
CAN-dongle.
The many functions of NIRA rk are described in detail starting in chapter 4.
NIRA rk is protected by applicable software copyright laws. You may not
distribute this software without the express written consent of Nira Control
AB. You may not copy this software other than for personal use. Your
purchase of NIRA i7x includes a single license to use NIRA rk together with
NIRA i7x.
1.1.4 Communication interface
The Kvaser CAN-dongle connects NIRA i7x to the PC running NIRA rk
software. The CAN-dongle connects to your PC via a USB port.
1.2 Glossary
Absolute pressure
Absolute pressure is measured starting at 0 kPa.
This is the pressure in vacuum. At sea-level the
absolute pressure is approximately 100 kPa, +/- 10
kPa depending on the weather (high or low
pressure.)
Alpha-N
Methodology to compute the amount of fuel to
inject based only on rpm and throttle angle.
Sometimes referred to as “throttle mapped.”
This mapping approach can be difficult to use and
requires a high resolution throttle position sensor
potentiometer.
On engines with aggressive camshaft profiles, the
pressure in the intake manifold fluctuates
significantly. In such cases it’s not possible to get a

Table of Contents