10 / 76 ♦ BKI16ATEX0018X ♦ htk4014a0600p_03
TECHNICAL DATA OF THE COATED PROBES
TYPE
HF--
HG--
HTX-- HTY-- HTM-- HTQ-- HTI--
Denomination
4mm FEP coated
cable
4mm FEP coated
cable
4mm FEP coated
cable
4mm fully FEP
coated cable
Fully PFA coated rod Fully PP coated rod
Max. measuring distance 24 m 24 m 24 m 24 m 3 m 3 m
Min. measuring distance
ε
r
= 80 / ε
r
= 2.4
0.3 m / 0.4 m 0.3 m / 0.4 m 0.3 m / 0.4 m 0.3 m / 0.4 m 0.3 m / 0.4 m 0.3 m / 0.4 m
Min. distance to objects
∅ 600 mm ∅ 600 mm ∅ 600 mm ∅ 600 mm ∅ 600 mm ∅ 600 mm
Min. medium ε
r
2.1 2.1 2.1 2.1 2.1 2.1
1” BSP
Process connection
1” NPT
DN 40 Triclamp DN 40 Milch
DN 50 DN 50 DN 50
Probe material 1.4401 / FEP 1.4401 / FEP 1.4401 / FEP 1.4401 / FEP 1.4571 / PFA 1.4571 / PP
Nominal diameter of the probe 6 mm 6 mm 6 mm 6 mm 12 mm 16 mm
Mass 0.16 kg/m 0.16 kg/m 0.16 kg/m 0.16 kg/m 0.5 kg/m 0.6 kg/m
Fillet and weight coating material – – – PFA PFA PP
Weight dimensions
∅ 25 x 100 mm ∅ 25 x 100 mm ∅ 25 x 100 mm ∅ 30 x 183 mm
– –
Weight material 1.4571 1.4571 1.4571 1.4571 – –
Max. medium temp.
+150 °C +150 °C +150 °C +150 °C +150 °C +60 °C
MEDIUM TEMPERATURE TABLE MEDIUM PRESSURE DIAGRAM
TYPE FLANGE TEMPERATURE
Transmitter –30 °C … +90 °C
High temp. HH_ or HP_ transmitter –30 °C … +200 °C
Lower or higher temperature for non-Ex version on special request
200°C
140°C
80°C
20°C
-30°C
-1 bar 16 bar 24 bar 32 bar 40 bar