EasyManua.ls Logo

NIVELCO MicroTREK - SPECIAL DATA FOR EX CERTIFIED MODELS

NIVELCO MicroTREK
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 / 76 BKI16ATEX0018X htk4014a0600p_03
SPECIAL DATA FOR EX CERTIFIED MODELS
TYPE
ALUMINIUM AND STAINLESS STEEL HOUSING
H--5,6,8
Ex marking (ATEX)
II 1 G Ex ia IIC T6…T3 Ga, II 1 G Ex ia IIB T6…T3 Ga
II 1 D Ex ia IIIC T85°C…T180°C Da, II 1/2 D Ex ta/tb IIICT85°C… T180°C Da/Db
Ex marking (IEC)
Ex ia llC T6...T3 Ga ; Ex ia llB T6...T3 Ga ; Ex ia lllC T85°C…T180°C Da ; -30 °C ≤ Tamb ≤ +60 °C
Intrinsically safe data (Ex ia IIB and Ex ia IIIC)
Ci ≤ 10 nF, Li ≤ 10 μH, Ui ≤ 30 V, Ii ≤ 140 mA, Pi ≤ 1 W
Intrinsically safe data (Ex ia IIC)
Ci ≤ 10 nF, Li ≤ 10 μH, Ui ≤ 30 V, Ii ≤ 100 mA, Pi ≤ 0.75 W
Medium temperature
–30 °C ... +200 °C (see Technical data – MEDIUM TEMPERATURE table)
Medium pressure
–0.1 … 4 MPa (-1…40 bar) (see Technical data – MEDIUM PRESSURE diagram)
T
EMPERATURE DATA
EXPLOSIVE GAS ATMOSPHERE EXPLOSIVE DUST ATMOSPHERE
ALUMINIUM AND STAINLESS STEEL HOUSING
H--8
ALUMINIUM AND STAINLESS STEEL HOUSING
H--5,6
HIGH TEMPERATURE
HH--8
HP--8
HIGH TEMPERATURE
HH--6
HP--6
Ex ia IIB, Ex ia IIC Ex ia IIIC/ Ex ta/tb IIIC
Maximum permissible medium
temperature at the antenna
+80°C +90°C +100°C +180°C +80°C +90°C +100°C +180°C
Maximum permissible surface
temperature at the process connection
+75°C +90°C +100°C +175°C +75°C +90°C +100°C +175°C
Temperature class T6 T5 T4 T3 T85°C T100°C T110°C T180°C

Related product manuals