3
Model Designation: NOBLE UH30 NOBLE UL30
Operating Capacity:
Racks per Hour 24 24
Dishes per Hour 600 600
Glasses per Hour 864 864
Tank Capacity (Gallons):
Wash Tank 1.1 1.2
Rinse Tank 1.1 3.0
Electrical Loads (as applicable):
Wash Motor HP 1.0
1.0
Rinse Heater KW 8.2 N/A
NOTE: Always refer to the machine data plate for specic electrical and water requirements.
The material provided on this page is for reference only and is subject to change without notice.
HOT WATER SANITIZING
Water Temperatures (Fahrenheit):
Minimum Wash Temperature 150 N/A
Minimum Rinse Temperature 180 N/A
Minimum Incoming Water Temperature 110 N/A
Chemical Sanitizing:
Water Temperatures (Fahrenheit):
Minimum Wash Temperature N/A 120
Minimum Rinse Temperature N/A 120
Minimum Incoming Water Temperature N/A 120
Other Water Requirements:
Water Flow Pressure (PSIG) 20 20
Flow Rate Minimum (GPM) 0.44 0.48
Water Line Size (NPT) 1/2" 1/2"
Drain Line Size (NPT) 1-3/8" 1/2"
Minimum Chlorine Required (PPM) N/A 50
OPERATING PARAMETERS