7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
System Management
Edition: 01 3HE 16132 AAAB TQZZA 653
sync-if-timing
Syntax sync-if-timing
Context show>system
Supported
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode; not supported on 7210 SAS platforms
configured in the standalone-VC operating mode
Description This command displays synchronous interface timing information.
Output The following outputs are examples of synchronous interface timing information, and
Table 90 describes the output fields.
• Sample Output for 7210 SAS-M
• Sample Output for 7210 SAS-R6 and 7210 SAS-R12
• Sample Output for 7210 SAS-T and 7210 SAS-Mxp
• Sample Output for 7210 SAS-Sx/S 1/10GE
• Sample Output for 7210 SAS-Sx 10/100GE
Sample Output for 7210 SAS-M
The following is a sample output for a node locked to the active BITS input and directing the
signal on ref1 to the BITS output.
*A:MTU>show>system# sync-if-timing
===============================================================================
System Interface Timing Operational Info
===============================================================================
System Status CPM A : Master Free Run
Reference Input Mode : Non-revertive
Quality Level Selection : Disabled
Reference Selected : none
System Quality Level : st3
Reference Order : ref1 ref2
Reference Input 1
Admin Status : down
Rx Quality Level : unknown
Quality Level Override : none
Qualified For Use : No
Table 89 Output Fields: System Timing
Label Description
System Up Time Displays the length of time the system has been up in days,
hr:min:sec format