Event and Accounting Logs
322
System Management Guide
3HE 11018 AAAC TQZZA Edition: 01
Parameters size — indicates the number of events that can be stored in the memory log
Values 50 to 3000
Default 100
to session
Syntax to session
Context config>log>log-id
Description This command instructs the events selected for the log ID to be directed to the current
console or Telnet session. This command is only valid for the duration of the session. When
the session is terminated, the log ID is removed. A log ID with a session destination is not
saved in the configuration file.
The command is one of the to commands used to specify the log ID destination. A to
command is mandatory when configuring a log destination.
The source of the data stream must be specified in the from command prior to configuring
the destination with the to command.
The to command can only be set once. It cannot be modified or re-entered. If the log
destination needs to be changed or if the maximum size of an SNMP log or memory log needs
to be modified, the log ID must be removed and then recreated.
Default No destination is specified
to snmp
Syntax to snmp [size]
Context config>log>log-id
Description This command instructs the alarms and traps to be directed to the snmp-trap-group
associated with the log-id.
A local circular memory log is always maintained for SNMP notifications sent to the specified
snmp-trap-group for the log-id.
The command is one of the to commands used to specify the log ID destination. A to
command is mandatory when configuring a log destination.
The source of the data stream must be specified in the from command prior to configuring
the destination with the to command.
The to command can only be set once. It cannot be modified or re-entered. If the log
destination needs to be changed or if the maximum size of an SNMP log or memory log needs
to be modified, the log ID must be removed and then recreated.