After Sales
Technical Documentation
RAE/RAK–1N
Service Software
Page 7– 9
Amendment 1 04/97
Figure 2. Servicing setup
DLR–1
+ –
to power
Supply
DAU–2/2T
COM1 COM2 LPT–1
PKD–1
PAS–1
Dummy Battery
PC
Minimum mode switch
Loading the Software
The program is delivered on a diskette and can also be installed on the
hard disk, which is recommendable to obtain maximum data access rate.
Do not lose your original diskette. It will be needed when upgrading the
program.
To start the program on diskette, proceed as follows:
1. Insert Service software diskette into drive A: of your PC
2. Log into drive A:
type A: press <Enter>
3. To run software
type rae_1 press <Enter>
To start the program on hard disk (if installed), proceed as follows:
1. Log into drive C:
type C: and press <Enter>
2. To run software
type rae_1 and press <Enter>