8 3.2 – Program Flash from File
This menu provides means to program the PDA Flash memory from a file
on the disk in the host.
Start Physical Address default: 3C00000h range: 3A00000h
3C00000h
3E00000h
Start Relative Address default: 000000h range: 000000h –
1FFFFFh
If the Start Physical Address is set to 3E00000h the maximum Start
Relative Address may not be greater than 1FFBFFh.
The output from the target shows the following:
whether the buffer filling was successful
whether the Flash programming was successful
3.3 – Save Flash to File
This menu provides means to read contents of Flash memory and to save
it to a file in the host service software PC.
User options are:
Start Physical Address default: 3C00000h Range: 3A00000h
3C00000h
3E00000h
Start Relative Address default: 000000h Range: 000000h – 1FFFFFh
End Physical Address default: 3E00000h Range: 3A00000h
3C00000h
3E00000h
End Relative Address default: 1FFFFFh Range: 000000h – 1FFFFFh
The output from the target shows the following:
whether the command was parsed successfully
whether the Flash reading to buffer has been successful
whether the transferring of the buffer contents has been successful.