3. I/Q Modulator Amplitude Balance and Phase Shift Tuning
The purpose of this tuning operation is to adjust the I/Q modulator d.c.
offsets and the I/Q modulator amplitude balance and phase shift.
I/Q modulator d.c. offsets, amplitude balance and phase shift tuning:
Connect spectrum analyzer (with attenuator if needed) to phone
antenna connector.
Select adjustment menu option ”TX I/Q Tuning” and press <Enter>.
Check that TX power level is level 5, channel is 700 and TX data type
is 1.
Adjust spectrum analyzer centre frequency to 1747,8 MHz, Span 200
kHz, Res BW 10 kHz, Video BW 1 kHz and Sweep time 0.5 s.
–67.71 kHz +67.71 kHz
CHF
> 30 dB
> 35 dB
Set this value
to minimum
Amplitude &
phase difference:
Set this value
to minimum
D.C. offset
tunings:
Select option ”TX I d.c. offset” and press <Enter>.
Adjust the level of centre frequency (CHF signal) to minimum by
varying D/A converter value with <+> and <–> keys.
When value is OK press <Esc>.
Select option ”TX Q d.c. offset” and press <Enter>.
Adjust the level of signal CHF to minimum by varying D/A converter
value with <+> and <–> keys.
When value is OK press <Esc>.