EasyManua.ls Logo

Nokia 9000i - Page 241

Nokia 9000i
434 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
After Sales
Technical Documentation
RAE/RAK–1N
Service Software
Page 7– 83
Amendment 1 04/97
Select option ”TX I and Q d.c. offset” and press <Enter>.
Adjust the level of signal CHF to minimum by varying D/A converter
value with <+> and <–> keys.
The amplitude difference between CHF–67.7 kHz and CHF should be
>30 dB.
When value is OK press <Esc>.
Select option ”Tune Amplitude Difference” and press <Enter>.
Adjust the level of signal CHF+67.7 kHz to minimum by varying D/A
converter value with <+> and <–> keys.
When value is OK press <Esc>.
Select option ”Tune Phase Difference” and press <Enter>.
Adjust the level of signal CHF+67.7 kHz to minimum by varying D/A
converter value with <+> and <–> keys.
The amplitude difference between CHF+67.7 kHz and CHF–67 kHz
should be >35 dB.
When value is OK press <Esc>.
Press <Esc> key and store new values with <Y> key.
4. Tuning of Transmitter Power Levels
This adjustment loads the power levels of the phone transmitter into the
EEPROM. When doing this, a pulse power meter or spectrum analyzer
must be used.
Note:
The cable loss of HCR–1 is about 2.4 dB
Power levels programming:
Set power supply voltage to 7.2 V.
Connect pulse power meter or spectrum analyzer to antenna
connector.
Check that channel is 700.
Select adjustments menu option ”TX Power Tuning” and press
<Enter>.
Press <Y>.
Adjust the power level (levels Base, 0, 8 and 10) with <+> and <–>
keys and change levels with <Up> and <Down> keys.

Table of Contents