After Sales
Technical Documentation
RAE/RAK–1N
Service Software
Page 7– 84
Amendment 1 04/97
Power
level
Tuning P
OUT
/dBm
(VB=7.2 V, CH700)
Base 0
tune first !
10 10
8 14
0 30
– Press <F3> to calculate all other levels.
– Once all TX levels are OK, press <Esc> and store readings in phone
EEPROM with pressing <Y>.
5. Charge Voltage Adjustment
A reference value for charge voltage is set by using an accurate 6.0 V
supply.
Calibration of the charge voltage:
– Apply +6 V to VCHAR line.
– Select adjustments menu option ”Charge Voltage Adjustment”.
– Program reads 6 V, A/D reading fed to phone VCHAR line.
– Store charge voltage value to phone EEPROM by pressing <Y>
6. Battery Voltage Adjustment
A reference value for battery are calibrated by using an accurate 6 V
supply.
Calibration of the A/D converter channels:
– Apply +6 V to dummy battery.
– Select adjustments menu option ”Battery Voltage Adjustment”.
– Program reads 6 V, A/D reading fed to phone VBAT line.
– Store correct value to phone EEPROM by pressing <Y>