EasyManua.ls Logo

Nordson 25B - Rebuilding Type-G Packing Glands

Nordson 25B
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Repair
7-20
E 1999 Nordson Corporation
All rights reserved
104 330H
Issued 8/99
Manual 1-8
Only Type G packing glands are rebuildable. Refer to the
Parts
section
for the kit part numbers. The kits contain all the parts necessary to
rebuild both upper and lower packing glands (upper only for the 2:1 and
4:1 ratio pumps).
1. See Figure 7-7. Remove the internal retaining ring (4), washer (5),
spacers (3) and U-cup (6). Inspect the external O-rings (1) and
replace if necessary.
2. Install a spacer (3) in the packing gland housing (2). Install the
U-cup (6) as shown in Figure 7-7.
NOTE: Make sure the washer is the proper size for the packing gland
housing. Some rebuild kits contain two washers. The smaller washer is
for the upper packing gland and the larger washer is for the lower
packing gland.
3. Install another spacer (3) on top of the U-cup (6). Place a washer (5)
on top of the spacer (3).
4. Using an internal retaining ring compression tool, install a retaining
ring (4), with the sharp edge on the flat facing away from the washer,
as shown in Figure 7-7.
01080013A
1
2
4
5
4
5
3
6
3
1
3
6
3
2
NOTE:RETAINING RINGS
INSTALL WITH SHARP EDGE
FACING AWAY FROM WASHER
NOTE:UPPER PACKING GLAND (TYPICAL)
INSTALL U–CUP FACE DOWN
NOTE:LOWER PACKING GLAND (TYPICAL)
INSTALL U–CUP FACE UP
NOTE:RETAINING RINGS
INSTALL WITH SHARP EDGE
FACING AWAY FROM WASHER
Fig. 7-7 Type-G Packing Glands—Cutaway View
1. External O-ring
2. Housing
3. Spacer
4. Internal retaining ring
5. Washer
6. U-cup
7. Rebuilding Type-G
Packing Glands