www.linearcorp.com 9 e3 eMerge Installation Instructions
Power Fault Connection
e controller is equipped with a power fault input that can be utilized as follows:
1. Determine whether your power fault input device uses a normally closed or normally open
con guration. Please refer to instructions provided by the manufacturer.
2. Connect the power fault input device to PIN 3 and PIN 4 on the terminal strip.
3. Verify that the power fault input device is functioning properly.
Figure 4.2. Power Fault Connection
Tamper Protection
A tamper switch is mounted inside the enclosure and is pre-wired to the tamper input on the
terminal strip. If the cover is removed for any reason the tamper switch will activate, triggering a
condition that can be linked to an event action in programming (e.g., send an e-mail or generate
an output).
Note: The system
settings must match the
requirement (normally
open or normally closed)
of the power fault
detection device.
TMP -
TMP +
FLT -
FLT +
+
Power Fault Input