www.linearcorp.com 2 e3 eMerge Installation Instructions
1.0 Introduction
is manual contains information regarding the basic installation, wiring and con guration of the
e3 eMerge browser-based access control systems. Systems are available in a space-e cient and
durable plastic housing or in a heavy-duty steel cabinet featuring a self-contained battery back-up
with a supervised power supply. All systems use the same control panel layout and system wiring.
1.1 Access Control Overview
Access control systems are designed to monitor and control access throughout a building or
restricted area. An access control system involves the use of an access device (card, PIN code,
etc.), which is presented at an entry device (reader/keypad) to gain access. When access is granted,
a door is unlocked for a pre-programmed amount of time and a transaction is recorded in a
database for reporting or tracking purposes.
1.2 System Overview
Systems are available in a variety of models starting with one door, two reader con gurations.
Models can be upgraded with expanded capabilities using optional software license keys. e
e3 eMerge includes Ethernet support, an integrated web server and Power over Ethernet (PoE)
support.
Specifications
Processor Cortex 1GHz
On-board RAM 512MB DDR2 (333MHz)
Power Regulated 12VDC @ 2A
Operating system Embedded Linux
Transactions per second > 30
Plastic enclosure (W x H x D): 12.25 in x 11.1 in x 2.23 in
Steel enclosure (W x H x D) 17.75 in x 14.25 in x 6.5 in
Temperature specification -4°F to 120°F (-20°C to 50°C)