www.linearcorp.com 16 e3 eMerge Installation Instructions
6.1 Wiring the Readers
e control panel can accept up to 8 readers or keypads. Each reader port on the panel supports a
12VDC reader with Wiegand output format. Readers can be installed as primary (entry) readers
for each door as well as optional secondary (exit) readers.
e maximum power available for individual reader is 750 mA @ 12 VDC with a combined
maximum of 1.5A for the controller. Determine the reader’s power consumption by referring to
the documentation included with the reader. Exceeding the maximum current for individual readers
or for the controller will damage the protection fuses and void the warranty.
Wiring Readers
1. Remove power from the control panel.
2. Pull the reader wiring through a knock-out in the panel’s enclosure.
3. Connect the color-coded wires from the reader’s wiring harness to the appropriate location
of terminal strip as shown in Figure 6.1.
4. Remove excess shield to ensure that it is not exposed. An exposed shield can cause
interference. Tape o any exposed shield with electrical tape.
Figure 6.1. Reader Wiring (typical)
Note: Wiring methods
shall be in accordance
with the National
Electrical Code/NPFA 70
and all local codes.
IN READER
RED
SILVER
Note: A green wire pigtail for
earth ground is provided in all
enclosures. Reader shields
must be properly grounded per
manufacturers installation
requirements.
12 V
LED
BUZZ
GND
IN D0
IN D1
OUT D0
OUT D1
GRN
WHT
BLK
OUT READER
RED
SILVER
12 V
LED
BUZZ
GND
IN D0
IN D1
OUT D0
OUT D1
GRN
WHT
BLK
6.0 Readers
Caution: Improper
power wiring will damage
the fuse and void the
warranty.
Minimum Cable
Speci cations:
Twisted, shielded 22
AWG (250 ft.) or 18
AWG (500 ft.) Belden
#9535 (5 conductor) or
equivalent. Please follow
manufacturers installation
requirements.