www.linearcorp.com 8 e3 eMerge Installation Instructions
4.0 System Power
e system panel requires a 12VDC, 2A supply (not included). For UL installations, a Linear
Plug in Power supply (PIP) is required (see below). e system may also be powered by a high
Power over Ethernet (PoE) injector using an optional Linear PoE module.
♦ Linear 12VDC/24W (2A) PIP; P/N 0-291312RU
♦ Linear 12VDC/60W (5A) PIP; P/N 0-299177RU (required for UL installations)
♦ Linear e3 PoE module; P/N 620-100159 (requires additional high power PoE injector). PoE
is not supported for installations requiring UL294.
4.1 Power Connection for Systems using Compact
Enclosure
Power Supply Connection
1. Connect 12VDC from the included power supply to the +12V and GND input terminals
on the panel. Note: e3 eMerge systems require a 12VDC, 2 amp Class 2 power supply. Incorrect
voltage will damage the product and void the warranty.
2. Connect an earth ground to the green earth ground lead provided in the enclosure.
3. Turn on the power supply. If using a PIP for the power supply, it must be plugged into a
dedicated receptacle that is not controlled by a switch.
4. e power LEDs (DL17 and DL9) on the panel will turn on to indicate power is present.
Figure 4.1. Power Connection
Note: Wiring methods
shall be in accordance
with the National
Electrical Code/NPFA 70
and all local codes.
MINIMUM
Cable Specifi cations for
power: Use a minimum
of 16 AWG Belden (2
conductor) or equivalent.
Maximum distance: 6
feet (1.8 meters).
Note: For PoE
applications only use
UL294B listed PoE
power supplies.
Caution: A 12VDC power
supply MUST be used.
Incorrect voltage will
damage the product and
void the warranty.
Note: Power should only
be applied to the system
when all connections are
secured and tested.
TMP -
TMP +
FLT -
FLT +
–
+
Earth
GND
12 VDC
12 VDC
12 VDC
+–
1 2 3
12VDC/24W PIP 12VDC/60W PIP
Connection for Linear PIP
1 2 3 4
EARTH
GROUND &
READER
SHIELD LEAD
Earth
GND
+–
Note: A green wire pigtail for
earth ground is provided in all
enclosures
-
+
Use 60W
PIP for the UL
installations.
Note: A separate power supply MUST be
used for door locks and accessories. A power
supply shared between the system and door
locks and accessories may cause damage or
intermittent operation.