Securing your system 65
The default snmp-server contact command is executed in the
Global Configuration command mode.
The default snmp-server contact command has no parameters
or variables.
snmp-server location command
The snmp-server location command configures the SNMP
sysLocation value. The syntax for the snmp-server location command
is:
snmp-server location <text>
The snmp-server location command is executed in the Global
Configuration command mode.
Table 22 "snmp-server location command parameters and variables"
(page 65) describes the parameters and variables for the snmp-server
location command command.
Table 22
snmp-server location command parameters and variables
Parameters and
variables
Description
<text>
Specifies the SNMP sysLocation value; enter an
alphanumeric string of up to 255 characters.
no snmp-server location command
The no snmp-server location command clears the SNMP sysLocation
value. The syntax for the no snmp-server location command is:
no snmp-server location <text>
The no snmp-server location command is executed in the Global
Configuration command mode.
Table 23 "no snmp-server location command parameters and variables"
(page 65) describes the parameters and variables for the no snmp-server
location command.
Table 23
no snmp-server location command parameters and variables
Parameters and
variables
Description
<text>
Specifies the SNMP sysLocation value. Enter a string of
up to 255 characters.
Nortel Ethernet Routing Switch 2500 Series
Security Configuration and Management
NN47215-505 (323165-B) 02.01 Standard
4.1 19 November 2007
Copyright © 2007, Nortel Networks
.

Table of Contents

Other manuals for Nortel 2526T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortel 2526T and is the answer not in the manual?

Nortel 2526T Specifications

General IconGeneral
Model2526T
Ports24
Uplink Ports2
LayerLayer 2
Power SupplyInternal
ManageableYes
Switching Capacity8.8 Gbps
Forwarding Rate6.5 Mpps
Jumbo Frame SupportYes
TypeManaged
FeaturesVLAN, QoS
Form FactorRack Mount
MAC Address Table Size8K entries
Operating Temperature0 °C to 40 °C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% (non-condensing)
Storage Humidity10 - 95% (non-condensing)