44205401TH Rev.1
132 /
Oki Data CONFIDENTIAL
7. Troubleshooting and repair procedure
Panel display
(The mark indicates no
message in the upper row.)
ON
LINE
lamp
Inspection
lamp
Details
Remedial
measure
Cancelling Job Blink Varies Indicates that canceling of a printing
without permission is in progress. (Job
Account related)
1. When a job is received from a user
that is not authorized to print.
2. When a color job is received from a
user that is not authorized to make a
color print.
−
Cancelling Job Blink Varies Indicates that canceling a job is in
progress because the log storage area
inside a printer has run out of memory
space, and the operation "Cancel the
job" is specified at log full.
(JobAccount)
−
Calibrating
Varies Varies Indicates RFID RD/WR checking is in
progress.
Adjusting Temp.
Varies Varies Indicates that a printer is in the midst
of cooling down. Note that (period) is
added at the end of message "Adjusting
the fuse temperature."
−
Adjusting Temp
Varies Varies Indicates that a printer is in the midst
of warming up. During this period, #0 of
the Leisus I/F: STSENG bit is "0".
−
Optimizing Temp
Varies Varies Indicates that printing is stopped
temporarily due to high temperature
of a drum. Alternately, this message
indicates that a printer is in the standby
state waiting for the thermal cooling
down when switching paper size from
narrow to wide.
−
Power Save
Varies Varies Indicates that a printer is in the power
save status.
When a printer enters the power save
mode, the LCD backlight turns off.
When it exits the power save mode, the
LCD backlight turns on. If the switch is
pressed while the backlight is off (in the
power save mode), the backlight turns
on, and then turns off in 30 seconds.
However, the power save mode is not
canceled. The backlight turns on during
shut-down (Priority 365).
−
Panel display
(The mark indicates no
message in the upper row.)
ON
LINE
lamp
Inspection
lamp
Details
Remedial
measure
Invalid Operation Varies Varies Pops up with the press of the Power
Save button while the printer cannot
switch to Power Save. Three seconds
after that, the display reverts to the one
before that.
The message is also displayed by
repeatedly pressing the button.
Color Adjusting
Varies Varies Indicates that the automatic color
registration correction is in progress.
−
Density Adjusting
Varies Varies Indicates that the automatic density
correction is in progress. The status
code 10988 corresponds to the density
read-out (Leisus – STSDEN #1) and
10994 corresponds to the density
correction (Leisus – STSDEN #0).
−
Flash Download Varies Varies Indicates that downloading of the PU
firmware program data is in progress.
Since downloading of the PU firmware
is opened internally only and not
disclosed to user, the status will not
occur in the user environment.
−