7. Troubleshooting and repair procedure
Display on operator panel
ON
LINE
lamp
Inspection
lamp
Contents Code nnn
Check Data
Program Data Receive
Error <nnn>
Off On Indicates that an error has occurred
during reception of the NIC program
data for upgrading.
%DLCODE%
1: Size error
2: Checksum error
3: Printer model number error
4: Module I/F version error
5: FAT version error
Error
Wait a Moment
Program Data Writing
Off Blink Indicates that writing of the NIC
program data for upgrading is in
progress.
Error
Power Off/On
Program Data Written OK
Off Off Indicates that writing of the NIC
program data for upgrading is in
complete.
Error
Check Data
Program Data Write Error
<nnn>
Off On Indicates that an error has occurred
during writing of the NIC program
data for upgrading.
%DLCODE%
1: Memory allocation error
2: Download file error
3: Device free space acquisition error
4: Device insufficient free space error
5: File write error
6: CU-F/W mismatch error
Error
Wait a Moment
Rebooting <n>
Off On Indicates the reboot of the controller
unit is progress.
%CODE% is a decimal value (single
digit) indicating cause of the reboot.
=0....Reboot that is resulted from a
cause other than the below.
=1....Reboot by the PJL command
=2....Reboot caused by the menu
change
=4....Reboot caused by the network
utilities (including web)
Error
Shutting down Off Off Indicates that a printer is shutting
down.
The shut-down process is started by
pressing the BACK button for more
than 4 seconds upon completion of
printer initialization process.
Error
Display on operator panel
ON
LINE
lamp
Inspection
lamp
Contents Code nnn
Turn off power
Shutdown completed
Off Off Indicates that the shut-down process
of a printer is complete.
(The LCD backlight turns off.)
Error
Power Off and Wait for a
while
126:Condensing Error
Off Blink Dew condensation error (This error
is handled in the same way as the
service call error though display only
is different.)
*The Fatal Errors are not supported
by the various languages.
Fatal
126
Power Off/On
nnn:Fatal Error
Off Blink Indicates that a fatal error has
occurred.
For detailed contents, refer to
"Service Calls List".
*The Fatal Errors are not supported
by the various languages.
Fatal
<nnn>
Service Call
nnn:Fatal Error
Off Blink Indicates that a fatal error has
occurred.
For detailed contents, refer to
"Service Calls List".
*The Fatal Errors are not supported
by the various languages.
Fatal
<nnn>
Service Call
nnn:Fatal Error *
Off Blink Indicates that a fatal error has
occurred.
For detailed contents, refer to
"Service Calls List".
The asterisk mark "*" indicates the
detailed information.
*The Fatal Errors are not supported
by the various languages.
Fatal
096
231
128
168
169
Power Off/On
nnn:Fatal Error
PC:nnnnnnnn
LR:nnnnnnnn
FR:nnnnnnnn
Off Blink Indicates that a fatal error has
occurred.
For detailed contents, refer to
"Service Calls List".
"nnnnnnnn" indicates the detailed
information.
*The Fatal Errors are not supported
by the various languages.
Fatal
002
011,
F0C
F0D
FFE
FFF
Power Off/On
209:Download Error
Off Blink Indicates failure of the Media table
downloading to PU.
(Custom Media Type related)
*The Fatal Errors are not supported
by the various languages.
Fatal
209

Table of Contents

Other manuals for Oki C711

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki C711 and is the answer not in the manual?

Oki C711 Specifications

General IconGeneral
Print TechnologyLED
ConnectivityUSB, Ethernet
Memory256 MB (max 768 MB)
Printer TypeWorkgroup Printer
Media SizesA4, A5, B5, Legal, Letter, Executive
Operating System CompatibilityWindows, Linux, Mac OS
Resolution1200 x 600 dpi

Related product manuals