Oki Data CONFIDENTIAL
44043511TH Rev.2
199 /
(2) CU Assy Troubleshooting (1200dpi Model)
a) Nothing is displayed on the LCD
CU PCB Malfunction
Has the power short-circuited on the CU PCB? (C7099: +5v)/ Does the LED
lightup normally? (PWR_GOOD Green: Light ON, IAG_LED3-0 Red: Light
OFF, FPGA_LED Green: Light ON) If NO GOOD, check to see if the
RAM DIMM is normally inserted.
Others
Power, Operation Panel, Fuse, etc.
b) "Communication Error" is displayed
CU PCB Malfunction
Does the LED lightup normally? (PWR_GOOD Green: Light ON, DIAG_LED3-0
Red: Light OFF, FPGA_LED Green: Light ON) If NO GOOD, remove in the
sequential order of RAM_DIMM and HDD. Does the Light On state vary?
If the LED Light On state is Normal, replace the applicable part.
If light ON is not normal, then replace PCB.
c) "Initializing" remains displayed.
CU PCB Malfunction
Does the LED lightup normally? (PWR_GOOD Green: Light ON, DIAG_LED
3-0Red: Light OFF, FPGA_LED Green: Light ON) If NO GOOD, remove in
the sequential order of RAM_DIMM and HDD. Does the Light On state vary?
If the LED Light On state is Normal, replace the applicable part.
If light ON is not normal, then replace PCB.
d) Error Message Display
Following the processing procedures of the Error Message in the table attach
-
ment.