210 /
Halogen Lamp
Thermistor
Bottom of Fuser Unit
1 2 3 4 5 6 4 3
7 6 5 4 3 2 1 2 1
6 poles
7 poles
Halogen Lamp
7-pole side
Pins 1 & 2: Non contact
Pins 3 & 4: Correction
Pins 5 & 6: Side thermistor
6-pole side
Pins 1 & 2: Lower thermistor
Fuser Unit Error
Immediately after turning ON the power, does a fuser error occur?
(A)
YES Are the three Upper Roller Thermistors down or short-circuited? (See
Figure 7-1.)
At an ambient temperature between 0 and 43˚C: 7-pole side:
Pins 1 & 2 = 4194 to 696.6k
Ω
Pins 3 & 4 =
642.1 to 122.4k
Ω
Pins 5 & 6 = 642.1 to 122.4k
Ω
YES Replace the fuser unit.
NO Is the thermistor on the lower side down or short-circuited? (See Figure 7-1.)
At an ambient temperature between 0 and 43˚C: 6-pole side:
Pins 1 & 2 = 642.1 to 122.4k
Ω
YES Replace the fuser unit.
NO
NO After turning ON the power, wait 3 minutes. Does a fuser unit Error occur?
NO Go to (A).
Is the fuser unit heater ON? (Is it HOT?)
YES Replace the engine control PCB.
NO Replace the fuser unit.
•NO Is there an AC voltage output between Pin 1 and Pin 3 of the CN1 connector of the
Low Voltage Power Unit?
NO Replace the low voltage power unit.
YES Replace the fuser unit.
Figure 7-1