7
EtherNet/IP Connection Procedure
18
8
IPADDR is displayed on Main
Display.
Press the ZERO/SET Key.
9
IP1 is displayed on Main
Display.
Press the ZERO/SET Key.
Check that 192 is displayed on
Sub-display.
*The set value here is the first
octet "192" of the IP address
192.168.250.50.
*If the value is different, press
the ZERO/SET Key.
The Sub-display changes to
the editing mode that enables
you to edit the value.
An editable digit of the value
blinks.
Select the digit you want to
change by pressing the
(RIGHT ) or the
(LEFT)
Keys.
Change the value by pressing
the
(UP) or the
(DOWN)
Keys.
Press the ZERO/SET Key
again to fix the set value.
Press the ZERORST/ESC Key.
The first menu shown in this
step is displayed again
Press the
(RIGHT ) Key.
192
000192
192